Installing the hot-swap power supply cage – Lenovo 6528 User Manual

Page 104

Advertising
background image

5. Disconnect the cables from the power-supply cage to the system board and all

internal components.

6. Remove the four black screws that secure the power-supply cage to the

chassis; then, slide the cage toward the front of the server to disengage the
retaining clips

1 from the top of the chassis and lift the cage out of the

chassis.

7. If you are instructed to return the power-supply cage, follow all packaging

instructions, and use any packaging materials for shipping that are supplied to
you.

Installing the hot-swap power supply cage

This procedure applies only to server models that have hot-swap power-supplies.

To install the hot-swap power supply cage, complete the following steps:

1. Place the power-supply cage into the chassis and slide it toward the rear of the

server until the retaining clips

1 engage the top of the chassis.

88

ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Installation and User Guide