Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the

Parts Listingsection in the Hardware Maintenance Manual to determine which components are

customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Fault in slot System board on system
%1.
(%1 = CIM_ComputerSystem.
ElementName)

Error

1. Check the extender-card

LEDs.

2. Reseat the affected adapters

and extender card.

3. Update the server and

adapter firmware (UEFI and
IMM).
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.

4. Remove both adapters.

5. Replace the PCI.

6. Replace the extender card.

7. (Trained service technician

only) Replace the system
board.

Redundancy Backup Mem Status
has been reduced.

Error

Redundancy has been lost
and is insufficient to continue
operation.

1. Check the system-event log

for DIMM failure events
(uncorrectable or PFA) and
correct the failures.

2. Re-enable mirroring in the

Setup utility.

IMM Network Initialization Complete.

Info

An IMM network has
completed initialization.

No action; information only.

Certificate Authority %1 has detected
a %2 Certificate Error.

Error

A problem has occurred with
the SSL Server, SSL Client,
or SSL Trusted CA certificate
that has been imported into
the IMM. The imported
certificate must contain a
public key that corresponds
to the key pair that was
previously generated by the
Generate a New Key and
Certificate Signing
Request
link.

1. Make sure that the certificate

that you are importing is
correct.

2. Try importing the certificate

again.

Ethernet Data Rate modified from %1
to %2 by user %3.
(%1 = CIM_EthernetPort.Speed;
%2 = CIM_EthernetPort.Speed;
%3 = user ID)

Info

A user has modified the
Ethernet port data rate.

No action; information only.