Lenovo 6528 User Manual

Page 162

Advertising
background image

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the

Parts Listingsection in the Hardware Maintenance Manual to determine which components are

customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Error code

Description

Action

0011002

Microprocessor mismatch

1. Run the Setup utility and view the microprocessor

information to compare the installed
microprocessor specifications.

2. (Trained service technician only) Remove and

replace one of the microprocessors so that they
both match.

0011004

Microprocessor failed BIST

1. Update the firmware (see “Updating the firmware”

on page 122).

2. (Trained service technician only) Reseat

microprocessor 2.

3. Replace the following components one at a time,

in the order shown, restarting the server each
time:

a. (Trained service technician only)

Microprocessor

b. (Trained service technician only) System

board

001100A

Microcode update failed

1. Update the server firmware (see “Updating the

firmware” on page 122).

2. (Trained service technician only) Replace the

microprocessor.

0050001

DIMM disabled

1. If the server fails the POST memory test, reseat

the DIMMs.

2. Remove and replace any DIMM for which the

associated error LED is lit (see “Removing a
memory module” on page 37
and “Installing a
memory module” on page 38).

3. Run the Setup utility to enable all the DIMMs.

4. Run the DSA memory test.

0051003

Uncorrectable DIMM error

1. If the server failed the POST memory test, reseat

the DIMMs.

2. Remove and replace any DIMM for which the

associated error LED is lit (see “Removing a
memory module” on page 37
and “Installing a
memory module” on page 38).

3. Run the Setup utility to enable all the DIMMs.

4. Run the DSA memory test.

0051006

DIMM mismatch detected

Make sure that the DIMMs match and are installed in
the correct sequence (see “Installing a memory
module” on page 38).

146

ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Installation and User Guide

Advertising
This manual is related to the following products: