Operating Your Appliance

21

© Travis Industries

100-01177

4060802

Bypass Operation

The bypass controls the flow of smoke inside the heater. When open, smoke goes directly up the flue,
creating more draft. When closed, the smoke goes through the combustor, utilizing the secondary
combustion system and making the heater more efficient.

When starting or re-loading the stove, open the bypass.

Once the stove reaches full temperature – typically 45 minutes, close the bypass.

To close the bypass, simply rotate the

handle down.

To open the bypass, push on the

lever and rotate the handle up.

Bypass CLOSED

Used for normal

operation

Bypass OPEN

Used for starting

and re-loading

If the bypass does not latch in the closed position, you will need to adjust the bypass latch (see page 33).

Loading Lid Operation

Open the lid 1" for a few

seconds to allow air to

enter the firebox.

Open the bypass first (this

helps prevent smoke from

entering the room).

Lift the lid upward.

A log poker is

provided with this
stove. It attaches

with a clip to to the

back of the stove.

WARNING: This part

becomes hot - use gloves.

a

b

Open the air control and allow air to flow

into the firebox for 30 seconds.

c

d

Do not wear loose clothing while re-loading the stove. Any item dangling above the opening may ignite.

Carefully close the loading lid after use. Allowing it to “slam” shut may damage the stove.