Operating your appliance 29, Troubleshooting problem possible cause – Lopi Leyden 028-S-75-2 User Manual

Page 29

Advertising
background image

Operating Your Appliance

29

© Travis Industries

100-01177

4060802

Troubleshooting

Problem

Possible Cause

Smoke Enters Room During
Start-Up

Open the bypass (pg. 21).

Open the air control (pg. 23).

Cold Air Blockage - burn a piece of newspaper to
establish a draft.

If the flame is not getting enough air, a small crack in
the door is all that is needed.

Kindling Does Not Start - Fire
Smolders

Open the bypass (pg. 21).

Open the air control (pg. 23).

Not enough starter paper - use additional newspaper if
necessary.

If the flame is not getting enough air, a small crack in
the door is all that is needed.

Smoke Enters Room While Re-
Loading

Open the bypass before opening the door (pg. 21).

Open the air control before opening the door (pg. 23).

Open the loading lid 1 inch and let air enter the firebox
for a few seconds. Once the smoke appears to be
flowing up the chimney consistently, open the loading
lid completely.

Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases a
small amount of smoke may enter the home. Adding
more pipe or a draft-inducing cap may help.

Stove Does Not Burn Hot Enough

Wood is Wet - see the section "Selecting Wood" on
page 26 for details on wood.

Make sure the air control is all the way open. Slide the
control back and forth to insure the control is not stuck.

Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases
the fire may burn slowly. Adding more pipe or a draft-
inducing cap may help.

Blower Does Not Run

Stove is Not Up to Temperature - This is normal. The
blower will come on when the stove is hot - usually 15
to 30 minutes.

Electricity is Cut to the Blower - Check the household
breaker or fuse to make sure it is operable.

Stove Does Not Burn Long
Enough

Depending upon wood, draft, and other factors, the
burn time may be shorter then stated. Make sure the
doors are sealing and not allowing air into the firebox -
See the section "Door and Glass Inspection" on page
31 for details.

Check the ash bed for coals. Often, coals are still
glowing under a slight bed of flyash. By raking these
into a pile you can re-start your stove quickly.

Advertising