Service Manual 17

Disassembly

12. Condenser

CAUTION: Discharge the refrigerant

system using a Freon

TM

Recovery

System. If there is no valve to attach the
recovery system, install one (such as a
WATCO A-1) before venting the Freon

TM

.

Leave the valve in place after servicing
the system.

1. Remove the cabinet. (Refer to section 2)
2. Remove the 4 screws that fasten the

brace.(Refer to section 4)

3. Remove the 5 screws that fasten the condenser

and shroud.

4. After discharging the refrigerant completely,

unbraze the interconnecting tube at the con-

denser connections.

5. Remove the condenser.
6. Re-install the components by referring to notes.

(See Figure 23)

13. Evaporator

1. Remove the control box.(Refer to section 3)
2. Remove the air guide upper. (Refer to section 4)
3. Remove the 2 screws that fasten the evapora-

tor.

4. Move the evaporator sideways carefully.

(Refer to section 4)

5. After discharging the refrigerant completely,

unbraze the interconnecting tube at the evapo-

rator connections.

6. Remove the evaporator.
7. Re-install the components by referring to notes.

(See Figure 24)

Refrigerating Cycle

14. Capillary Tube

1. Remove the cabinet. (Refer to section s2)
2. After discharging the refrigerant completely,

unbraze the interconnecting tube at the capillary

tube.(See caution above)

3. Remove the capillary tube.
4. Re-install the components by referring to notes.