Installation

How to Install

Window Requirements

All supporting parts should be secured to
firm wood, masonry, or metal.

1. This unit is designed for installation in standard double

hung windows with actual opening widths of 22" to 36".

The upper and lower sash must open sufficiently to allow

a clear vertical opening of 13" from the bottom of the

sash to the window stool.

2. If storm window presents interference, fasten a 2" wide

wood strip to the inner window sill across the full width of

the sill. The wood strip should be thick enough to raise

the height of the window sill so that the unit can be

installed without interference by the storm window

frame. See Figure. 4. Top of wood strip should be

approximately 3/4" higher than the storm window frame

(STORM WINDOW FRAME) or wood strip (OUT-

DOORS) to help condensation to drain properly to the

outside.

3. Install a second wood strip (approximately 6" long by 11/2"

wide and same thickness as first strip) in the center of the

outer sill flush against the back off the inner sill. This will

raise the L bracket as shown Figure. 4.

4. If the distance between STORM WINDOW FRAME and

WOOD STRIP MOUNTED ON TOP OF INNER SILL is

more than 1", two of wood strip are not necessary.

Installation

NOTICE

OUTDOORS

INDOORS

INNER

SILL

OUTER

SILL

INNER

SILL

WOOD STRIP MOUNTED

ON TOP OF INNER SILL

WOOD STRIP

FOR

L

BRACKET

3/4"

CLEARANCE

1" MAX.

STORM

WINDOW

FRAME

OUTDOORS

INDOORS

OUTER

SILL

Figure 3

Figure 4

HARDWARE

TYPE E: 1EA

(SASH SEAL)

(Not adhesive backed)

TYPE D: 1EA

(SEAL STRIP)

(Adhesive backed)

TYPE F: 2EA

(GUIDE PANEL)

TYPE C: 3EA

(

L

BACKET)

TYPE A: 11EA

(SHORT SCREW)

10mm

TYPE B: 5EA

(WOOD SCREW)

16mm

TYPE G: 1EA

(SUPPORT BACKET)

DRAIN PIPE

Advertising