Service Manual 35

Troubleshooting Guide

COMPLAINT

CAUSE

REMEDY

Check the TEMP control. If not at the lowest number,

set TEMP control to this setting and restart the unit.

Check the continuity of the thermistor. Replace the

thermistor if the circuit is open.
Check the capacitor.

Replace if not within ±10% of manufacturers rating.

Replace if shorted, open, or damaged.
Check the compressor for open circuit or ground. If

open or grounded, replace the compressor.
Check the compressor overload, if externally mount-

ed. Replace if open. (If the compressor temperature

is high, remove the overload, cool it, and retest.)
Check the voltage.

If not within limits, call an electrician.
Check overload, if externally mounted.

Replace if open. (If the compressor temperature is

high, remove the overload, cool, and retest.)
If not running, determine the cause. Replace if

required.
Remove the cabinet. inspect the interior surface of

the condenser; if restricted, clean carefully with a vac-

uum cleaner (do not damage fins) or brush. Clean the

interior base before reassembling.
If condenser fins are closed over a large area on the

coil surface, head pressures will increase, causing

the compressor to overload. Straighten the fins or

replace the coil.
Test capacitor.
Check the terminals. If loose, repair or replace.
Check the system for a restriction.
If restricted, clean of replace.
Close if open.
Determine if the unit is properly sized for the area to

be cooled.
Check the set screw or clamp. If loose or missing,

correct. If the turbo or fan is hitting air guide,

rearrange the air handling parts.
Remove the cabinet carefully and rearrange tubing

not to contact cabinet, compressor, shroud, and barri-

er.

Thermistor

Capacitor (Discharge

capacitor before servicing.)

Compressor

Overload

Voltage

Overload

Fan motor

Condenser air flow restric-

tion

Condenser fins (damaged)

Capacitor
Wiring
Refrigerating system
Air filter
Exhaust damper door
Unit undersized

Turbo or fan

Copper tubing

Compressor will not run,

but fan motor runs.

Compressor cycles on

overload.

Compressor cycles on

overload.

Compressor cycles on

overload.

Insufficient cooling or heat-
ing

Excessive noise

Advertising