24 Room Air Conditioner

Troubleshooting Guide

Troubleshooting Guide

In general, possible trouble is classified in two kinds.
The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air

Conditioning caused by a defect in the refrigeration circuit and improper application.

Unit runs but poor cooling.

Ineffective Cooling

Check outdoor coil

(heat exchanger) & the fan

operation.

Check gas leakage.

Repair gas leak.

Replacement of unit if the

unit is beyond repair.

Satisfactory operation with

temperature difference of

inlet & outlet air ;

44~50

°

F(7~10

°

C)

Check heat load

increase.

Clean condenser.

Not on separate circuit.

Check inside gas

pressure.

Adjusting of refrigerant

charged.

Malfunction of compressor.

Replacement of

compressor.

Check cold air circulation

for smooth flow.

Dirty indoor coil

(Heat exchanger)

Correct above trouble

Check clogging in refrigera-

tion circuit.

Repair clogging in refrigera-

tion circuit.

Obstruction at air outlet

Clogged of air filter.

Malfunction of fan