8 Room Air Conditioner

Installation

Installation

Select the Best Location

Installation Check

How to Secure the Drain Pipe

1. To prevent vibration and noise, make sure the unit is installed

securely and firmly.

2. Install the unit where the sun does not shine directly on the

unit.

3. The outside of the cabinet must extend outward for at least

12" and there should be no obstacles, such as a fence or

wall, within 20" from the back of the cabinet because it will

prevent heat radiation of the condenser.

Restriction of outside air will greatly reduce the cooling effi-

ciency of the air conditioner.

CAUTION:

All side louvers of the cabinet must

remain exposed on the outdside of the structure.

4. Install the unit slanted slightly so the back is slightly lower

than the front (about

1

/

4

"). This will force condensed water

to the outside.

5. Install the unit with the bottom about 30"~60" above the

floor level.

The setting conditions must be checked prior to initial starting.
The following items are especially important checking points when the installation is finished.

1. Grounding wire (Green or Green and Yellow) is provided in the power cord. The green wire must be grounded.
2. Connect to a single-outlet 15A circuit.

(or 20A circuit for Electric Heater Model)

3. To avoid vibration or noise, make sure the air conditioner is installed securely.
4 Avoid placing furniture or draperies in front of the air inlet and outlet.

In humid weather, excess water may cause the Base Pan to

overflow. To drain the water, remove the Drain Cap and secure

the Drain Pipe to the rear hole of the Base Pan. (Figure. 2)

Figure 2

ABOUT / "

Over 20"

HEAT

RADIATION

FENCE

AWNING

OUTSIDE

INSIDE

COOLED AIR

30"-60"

1

4

Figure 1

Drain Pipe

Drain Cap