Installation, Rated input - single phase only – Lincoln Electric TIG 275 User Manual

Page 10

Advertising
background image

A-1

INSTALLATION

PRECISION TIG 275

A-1

TECHNICAL SPECIFICATIONS-PRECISION TIG 275 (K1827-2 Export-50/60Hz)

Voltage + 10%

220-230/

380-400/415

Max. Amps With Out

Power Factor Capacitor

95/55/50

109/63/58

80/46/42
85/49/45

70/41/37
65/38/35

10/6/5

400W

Max. Amps With

Power Factor Capacitor

80/46/43
86/50/46

64/37/34
67/39/36

52/30/28
46/27/25
23/13/12

500W

Duty Cycle-Applications

40%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

60%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

100%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

Idle Amps

Idle Power

RATED INPUT - SINGLE PHASE ONLY

K

Number

K1827-2

*Shown on Front of this IM manual with Advanced Control Panel (Refer to Optional Equipment)

#

Exceeds NEMA Unbalanced Load Specification comparable for Auto-Balance.

RATED POWER FACTOR (STICK) K1827-2

.65 min.

.77 min.

IEC 60974-1