B-11

OPERATION

B-11

PRECISION TIG 275

Max. to Min.

Amptrol

Min. to Max.

Amptrol

Setup for TIG Amptrol Welding

Advanced Panel

(If used)

Standard Controls

Power Switch

ON

Polarity Switch

AC

or DC

-

Mode Switch

TIG

AC Balance

AUTO

or

Set:

More +

for alum.oxide "Cleaning"
w/o "Spitting" or "wetting" loss.

Balanced for equal + and

- current.

More -

for higher "Penetration".

Local/Remote

Switch

REMOTE

Trigger Switch

2-STEP

Pulse Switch

ON

or OFF

Pulse Frequency

4-6 pps is a typical initial setting.

Set for bead shape and travel speed:

Higher for thinner plate and faster travel.
Lower for thicker plate and slower travel.

% On Time

40-60% is a typical initial setting.

Set for total heat of Peak current:

Lower reduces distortion and burn-thru.

Background Current

40-60% is a typical initial setting.

Set as low as will maintain a pulse arc

(Will not drop below Min.Output setting.)

Downslope

ZERO

For no arc-out delay.

Minimum Output

Press Display switch

and Set to desired min.

Amptrol (Start/Crater)

output level.

Postflow

Set as low as required.

Higher for larger

tungsten and current.

Maximum Output

Set to desired max.

Amptrol output level.

FIGURE B.6

Controls

The new foot pedal provides such independent action
distinction of precisely where the arc start switch actu-
ates without over-riding minimum control pedal posi-
tion, and precisely where the control pedal has been
returned to minimum position without inadvertently de-
actuating the arc start switch. The result is repeatable
consistency in TIG weld starting and crater-fill for man-
ual process control.

Using this new foot pedal with the Precision TIG

s new

presettable Minimum Output level, in addition to the
presettable Maximum Output level, further enhances
the starting and crater level consistency as well as the
control resolution of the manually controlled foot pedal.

Toe

Pressure

Switch

Foot

Rock

Control

Adjustable

or

Removable

Heel Stop

Fully Pressed
Control Pedal

Maximum Output
Machine Setting

Minimum Output
Machine Setting

At-Rest
Control Pedal

Pressed
Switch Pedal

At-Rest
Switch Pedal

Off

Time

FIGURE B.5