Installation, A-2 additional output capacity, Physical dimensions – Lincoln Electric TIG 275 User Manual

Page 11: Temperature ranges, Recommended input wire and fuse sizes

Advertising
background image

K1827-2

A-2

INSTALLATION

PRECISION TIG 275

A-2

ADDITIONAL OUTPUT CAPACITY

Output Current

Range

2Amps DC

to

340Amps AC-DC

*

Type of Output

CC (Constant Current)

AC/DC (GTAW)

Stick (SMAW)

Maximum Open

Circuit Voltage

(STICK AND TIG)

AC/DC OCV: 75/68

Auxiliary Power

15Amp Circuit Breaker and NEMA 5-15R Duplex

Receptacle for up to:

115VAC 8Amp Auxiliary Power Receptacle

115VAC weld Switched Cooler Receptacle load

5 Amp Circuit Breaker

and grounded 220VAC

Euro(Schuko) receptacle

Height

Width

Depth

Weight

31.0 in.

22.0 in.

26.0 in.

Approx. 397 lbs.

787 mm

559 mm

660 mm

180 kgs.

PHYSICAL DIMENSIONS

1

ALSO CALLED

INVERSE TIME" OR "THERMAL/MAGNETIC " CIRCUIT BREAKERS; CIRCUIT BREAKERS WHICH HAVE A DELAY IN TRIPPING ACTION THAT DECREASES AS

THE MAGNITUDE OF CURRENT INCREASES.

*

50/60H

Z

IEC Max. range exceeds 310A.

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-20

°

C to +40

°

C (-04

°

to +104

°

F)

TRANSFORMER INSULATION CLASS 180°C (H)

STORAGE TEMPERATURE RANGE

-40

°

C to +85

°

C (-40

°

to +185

°

F)

For all Stick, DC TIG, and Balanced AC TIG Welding

at 275A/40% Duty Cycle with out Standard Power

Factor Correction Capacitors

Based on the 1999 U.S. National Electrical Code

For Unbalanced AC TIG Welding Above 275 Amps:

255A/40% Duty Cycle, Auto-Balance Penetration with

out Standard Power Factor Correction Capacitors

Based on the 1999 U.S. National Electrical Code

RECOMMENDED INPUT WIRE AND FUSE SIZES

Input

Voltage /

phase/

Frequency

220-230/1/50/60

380-400/1/50/60

415/1/50/60

Input

Ampere

Rating

Rating on

Nameplate

95

55

50

Input

Ampere

Rating

109

63

58

Type 75°C

Copper

Ground Wire in

Conduit AWG

(IEC) Sizes

6 (13.3 mm2)

8 (8.4mm2)

8 (8.4mm2)

Type 75°C

Copper

Ground Wire in

Conduit AWG

(IEC) Sizes

6 (13.3 mm2)

8 (8.4 mm2)

8 (8.4 mm2)

Fuse

(Super Lag)

or Breaker

Size

1

125

80

80

Fuse

(Super Lag)

or Breaker

Size

1

150

90

90

Type 75°C

Copper Wire in

Conduit AWG

(IEC) Sizes

40°C (104°F)

Ambient

4 (21.2 mm2)

8 (8.4mm2)

8 (8.4mm2)

Type 75°C

Copper Wire in

Conduit AWG

(IEC) Sizes

40°C (104°F)

Ambient

4 (21.2 mm2)

6 (13.3 mm2)

6 (13.3 mm2)

RATED OUTPUT - IEC 60974-1 (K1827-2)

Duty Cycle-Applications

40%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

60%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

100%

AC/DC Stick / Balance TIG

Unbalance (70% Penetration

#

) AC TIG

Volts at Rated Amperes

31.0
20.2

29.0
18.0

28.0
16.0

Amps

275
255

225
200

200
150

Advertising