CAUTION

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Thermal light comes on

Meter doesn

t light up

Has output in No gas & no hi-freq
Stick mode
but no output
in Tig mode

Gas & hi-freq are o.k.

No output in both Stick and Tig
modes

1. Thermal shut down. Dirt and dust

may have clogged the cooling
channels inside machine; air
intake and exhaust louvers may
be blocked; welding application
may exceed recommended duty
cycle. Wait until machine cool
down and thermal light goes out.
Blow out machine with clean, dry
low pressure air; check air intake
and louvers; stay within recom-
mended duty cycle.

2. Bad thermostat or its connections

1. Losing AC supply to Control PC

board

2. Loosing input to machine

3. Faulty Control PC board

1. Faulty trigger or hand/foot Amptrol

or connections.

2. Faulty Protection PC board or

bad connection to Control PC
board

3. Losing trigger supply to Control

PC board

1. Faulty Control PC board

1. Bad connection at P4 of Control
PC board

2. Faulty Control PC board

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.