E-5

TROUBLESHOOTING

E-5

PRECISION TIG 275

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

PRESET & OUTPUT CONTROL PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Meter does not display preset

High output current in both DC & AC
polarities regardless of preset

High output current in DC polarity
regardless of preset, o.k. in AC polar-
ity

In 2-step Tig, output stays on for
more than downslope time after trig-
ger open (machine with Advanced
Control panel only)

Output stays on after releasing
hand/foot Amptrol (machine with
Advanced Control panel only)

1. Faulty potentiometer R1 or its con-

nection

2. Bad connection at P9 of Control

PC board

3. Faulty Advanced Control PC board

( if present ) or its connection to
the main Control PC board

4. Missing plug P3 on Control board

or bad connection at P3 when an
Advanced Control PC board is not
present

1. Bad connection at P6 of Control

PC board

2. Bad shunt connection

3. Faulty Control PC board

4. Faulty SCR bridge

1. Shorted free wheeling diode D1

1. Bad 2/4 step switch or its connec-

tion

2. Bad connection at P1 of Advanced

Control PC board

1. Downslope is not set at min.

2.

Bad Downslope potentiometer
R12 or its connection

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.