Troubleshooting, Caution – Lincoln Electric TIG 275 User Manual

Page 36

Advertising
background image

E-4

TROUBLESHOOTING

E-4

PRECISION TIG 275

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

HI-FREQ PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

No hi-freq

Hi-freq intensity too weak

Hi-freq on continuously in DC Tig

Hi-freq shuts off after starting in AC
Tig

1. Circuit breaker CB1 open

2. Bad connection at P12 of Control

PC board

3. Spark gaps shorted

4. Faulty Control PC board

1. Dirty spark gap or improper gap

setting

2. Faulty Arc Starter assembly

1. Bad connection at P11 of Control

PC board

2. Micro-switch S2A is not engaged &

disengaged properly when switch-
ing between DC & AC polarity.
(S2A locates on the Polarity
switch)

3. Faulty Control PC board

1. Micro-switch S2A is not engaged &

disengaged properly when switch-
ing between DC & AC polarity.
(S2A locates on the Polarity
switch)

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.