Menus which are displayed, Menu management accompanying, Switching the system frequency – Panasonic AJ-HD1800P User Manual

Page 113: Setup menus

Advertising
background image

113

Setup menus

(continued)

<Menu management accompanying switching the system frequency>

The system menu and setup menu have some items whose settings differ and other items with which no selection options are
displayed and whose settings are fixed, depending on the switching of the operation mode in response to the setting selected
for system menu item No.25 (SYSTEM FREQ). (Refer to the table below.)

System menu and setup menu settings

z Each of the items whose settings differ is saved in the VTR

MEMORY (current file and one of the backup files 1 to 4).
The settings that correspond to each operation mode will
be displayed so that the settings can be performed for
each operation mode.

Registration of the <PF1> and <PF2> function
buttons

z When the items whose settings differ have been

registered in the <PF1> and <PF2> function buttons, the
settings that correspond to each operation mode will be
displayed so that the settings can be performed for each
operation mode.

z If items, whose selection options are not displayed due to

the operation mode, have been registered in the <PF1> or
<PF2> function button, when an operation mode in which
these options are not displayed is selected, what has been
registered is saved but the function button itself will
become blank and cannot be operated. Note that the
registered contents on items that are not displayed will be
deleted during the following operations.

z When the set value in Setup Menu No. 600 (VIDEO IN

SEL) changes from SD SDI to another set value or
from another set value to SD SDI.

z When the set value in Setup Menu No. 650 (STYLE)

changes.

<50P IN/OUT> 50-pin connector registration

z When the items whose settings differ have been

registered in the <50P IN/OUT> 50-pin connector pins, the
settings corresponding to the operation modes are
allocated to the IN and OUT pins on the basis of the
setting numbers. However, when the upper limit value is
exceeded, the value will be limited to this upper limit.
What has been registered is saved, but bear in mind that
when the data is registered again, it is saved by
overwriting the existing data so that the previously
registered data will be lost.

z If items, whose selection options are not displayed due to

the operation mode, have been registered in the <50P IN/
OUT> 50-pin connector, when an operation mode in which
these options are not displayed is selected, what has been
registered is saved but no operation is possible. Note that
the registered contents on items that are not displayed will
be deleted during the following operations.

z When the set value in Setup Menu No. 600 (VIDEO IN

SEL) changes from SD SDI to another set value, or
from another set value to SD SDI,

z When the set value in Setup Menu No. 650 (STYLE)

changes.

<Menus which are displayed>

The menus displayed differ depending on the setting selected for menu item No.25 SYSTEM FREQ.

NO.

Menu item

System menu No.25 (SYSTEM FREQ)

59/60

23/24

50i/25P

25 (HD)

25 (SD)

50 (HD)

50 (SD)

05 ENCODER SEL

06 V LEVEL CTRL

12 SYS H (HD)

14 SYS SC (SD)

15 VO SYS H (SD)

16 SD SYS H (SD)

18 SCH (SD)

20 AV PHASE

25 SYSTEM FREQ

26 HD SYS H ADV

No

No

No

No

No

No

30 MENU LOCK

000 P-ROLL TIME

001 LOCAL ENA

002 TAPE TIMER

No

No

No

No

No

003 REMAIN SEL

004 SYNCRONIZE

No

No

No

No

No

005 SUPER

006 DISPLAY SEL

007 CHARA H-POS

008 CHARA V-POS

009 CHARA TYPE

010 MONI CONTROL

No

No

No

No

No

011 CU-ROLL TIME

Advertising