Interface, Setup menus, Continued) <interface – Panasonic AJ-HD1800P User Manual

Page 90

Advertising
background image

90

Setup menus

(continued)

<INTERFACE>

The underlining (__) denotes the factory setting mode.

No./Item

Description of setting

200

PARA RUN

For selecting whether to operate two or more
VTRs in synchronization.
0000

DIS

The VTRs are not operated in synchronization.

0001

ENA

The VTRs are operated in synchronization.

<Note>
To operate the VTRs in synchronization, set all the
VTRs to 1 (ENA). (Refer to page 16.)

202

ID SEL

For setting what ID information is to be
returned to the controller.
0000

OTHER

For setting the ID information of a VTR other
than DVCPRO

0001 DVCPRO

For setting the ID information of the DVCPRO

0002

ORIG

Set only for connecting with the Panasonic
controller (AG-A850, optional).

204

RS2323C SEL

For selecting whether the RS-232C connector is
to function.
0000

OFF

The RS-232C connector does not function.

0001

ON

The RS-232C connector functions.

205

BAUD RATE

For setting the RS-232C data transfer speed
(baud rate).

0000

300

0001

600

0002

1200

0003

2400

0004

4800

0005

9600

206

DATA
LENGTH

For setting the RS-232C data length.
(Unit: bits)

0000

7

0001

8

207

STOP BIT

For setting the number of RS-232C stop bits.
(Unit: bits)

0000

1

0001

2

208

PARITY

For setting whether the RS-232C parity bit is to
be used and, if it is used, whether even or odd
parity is to apply.

0000

NON

The parity bit is not used.

0001

ODD

The parity bit is used with an odd parity.

0002

EVEN

The parity bit is used with an even parity.

No./Item

Description of setting

209

RETURN ACK

For setting whether or not to return the ACK
code when a command is received from RS-
232C.

0000

OFF

The ACK code is not returned

0001

ON

The ACK code is returned.

212

MASTER
PORT

For selecting the remote control connector for
controlling the slave machine when this VTR is
to be used as the master machine for deck-to-
deck operations.

0000

IN/OUT

The IN/OUT connector is used.

0001

OUT

The OUT connector is used.

<Note>

This setting takes effect only when the 9P button
has been set to LOCAL (LED off).

Advertising