Panasonic WJ-RT208 User Manual

Page 41

Advertising
background image

41

RS485 setup (RS485 SETUP)

Refer to the step (7) in 2.5.

Data port setup (DATA PORT SETUP)

The settings relating to the serial data communication can
be configured on "DATA PORT SETUP" of "COMMUNICA-
TION SETUP" on the "WJ-RT208 SETUP MENU".

(1) Press the [MENU] button. The "WJ-RT208 SETUP

MENU" will be displayed.

(2) Move the cursor onto "COMMUNICATION SETUP" and

press the [SET] button.
The "COMMUNICATION SETUP" menu will be dis-
played.

(3) Move the cursor onto "DATA PORT SETUP" and press

the [SET] button.
The "DATA PORT SETUP" menu will be displayed.

(4) Configure the following setup items.

• "Unit Address (System)"

A unit address (System) is a unique number assigning
to PS·Data devices. The addresses must be unique to
identify system devices when connecting multiple
devices compatible with PS·Data.
Numbers, "001"-"099", are to be assigned as the unit
addresses to the system devices.

• "Baud Rate"

Select the communication speed for data transmission
with a connected device from the following.
2 400/4 800/9 600/19 200/38 400 bps

• "Data Bit"

It is impossible to change the value for this setting.
8 (bit)

"Parity"

Select a method to check a transmission error at com-
munication from the following.
"None": No parity check
"Even": Even parity
"Odd": Odd parity

"Stop Bit"

Select a stop bit from the following.
1 bit/2 bit

"Retry Timing"

Select a retransmission interval for when data reception
is not confirmed from the following.
OFF/100 ms/200 ms/400 ms/1 000 ms

"Alarm Data"

Select a method to inform the connected controller of
an event occurrence from the following.
"Off": Does not function.
"0s": Informs the controller every time an event is

detected.

"1s/5s": Informs the controller when a specified time

has passed after detecting an event.

"Channel No."

It is possible to assign a number to each camera chan-
nel to operate cameras using the controller compatible
with PS·Data.
Do the following to assign numbers to the camera chan-
nels.

(1) Move the cursor onto "Channel No." and press the

[SET] button.
The "Channel No." menu will be displayed.

COMMUNICATION SETUP

NETWORK SETUP

RS485 SETUP

DATA PORT SETUP

WJ-RT208 SETUP MENU

SYSTEM MANAGEMENT

SEARCH

REC&EVENT SETUP

PTZ SETUP

CAMERA SETUP

COMMUNICATION SETUP

REPORT

USER INFORMATION

DATA MANAGEMENT

DATA PORT SETUP

001

Unit Address (System)

9600

Baud Rate

8

Data Bit

None

Parity

1

Stop Bit

Off

Retry Timing

1s

Alarm Data

Set

Channel No.

OK