Pelco DX2000 User Manual

Page 15

Advertising
background image

Pelco Manual C690M-E (11/04)

15

2. Connect the cameras. Plug standard coaxial cables (not supplied) from the cameras into

the top row of BNCs on the rear of the DVR. Camera 1 is the top left BNC. Set rear panel
DIP switch 3 to the correct position (UP=NTSC, DOWN=PAL). Set the video termination
switches to the proper setting: 75 ohms if no equipment is connected to the BNC looping
connector; HZ if equipment is connected to the BNC looping connector.

3. Connect a video monitor (if desired). The monitor will show a live camera view and will

follow the view selected on the controlling PC. Plug a standard coaxial cable (not sup-
plied) from a monitor into the MON OUT BNC on the DVR. Properly terminate (75 ohms)
at the monitor.

4. Set DIP switch 3 for NTSC/PAL operation. Set the alarm DIP switches (if desired) accord-

ing to the information in the

Connecting Alarms section.

5. Connect alarms (if desired). Wiring gauge is not critical, but the maximum resistance

between alarm input and contact closure should be less than 150 ohms. Refer to the
Connecting Alarms section for detailed information.

6. Connect relays (if desired). Connect mechanisms you want to control remotely, such as a

gate or door, to relays 1 and 2 (REL 1, REL 2). Use the C (common) post and either NO
(normally open) or NC (normally closed) depending on how you want the relay to operate.

An external fuse is required to protect against currents above 1 amp.

7. Connect POS terminals and/or ATMs (if desired). Refer to the

Connecting POS Terminals

and ATMs section for details.

8. Connect power. Plug one end of the appropriate supplied power cable (USA or European

standard) into the receptacle on the rear of the DVR and the other end into a power outlet.

Advertising