Server Management

Intel® SHG2 DP Server Board Technical Product Specification

Intel Order Number C11343-001

Revision 1.0


30

5.1 Sahalee Baseboard Management Controller

The Sahalee BMC contains a 32-bit RISC processor core and associated peripherals used to
monitor the system for critical events. The Sahalee BMC, packaged in a 156-pin BGA,
monitors all power supplies, including those generated by the external power supplies, and
those regulated locally on the server board. The Sahalee BMC also monitors SCSI termination
voltage, fan tachometers for detecting a fan failure, and system temperature. Temperature is
measured on each of the processors and at locations on the server board away from the fans.
When any monitored parameter is outside of defined thresholds, the Sahalee BMC logs an
event in the System Event Log (SEL).

Management controllers and sensors communicate on the I

2

C-based Intelligent Platform

Management Bus (IPMB). Attached to one of its private I

2

C bus is Heceta5*, an ADM1026*,

which is a versatile systems monitor ASIC. Some of its features include:

Analog measurement channels

Fan speed measurement channels

General-Purpose Logic I/O pins

Remote temperature measurement

On-chip temperature sensor

Chassis intrusion detect

Table 18 details some of the inputs on the Heceta5 (ADM1026) as used on the SHG2 server
board.

Table 18. ADM1026* Input Definition

Pin

ADM1026 Signal Name

Type

External Signal Name / Function

1

GPIO9

Digital Input

CPU2_IERR / CPU2 IERR

2

GPIO8

Digital Input

CPU1_IERR / CPU1 IERR

3

FAN0/GPIO0

Digital Output

ADM_DIS_CPU1_L / CPU1 Stop Clock

4

FAN1/GPIO1

Digital Output

ADM_DIS_CPU2_L / CPU2 Stop Clock

5

FAN2/GPIO2

Digital Input

Not connected / None

6

FAN3/GPIO3

Digital Input

Not connected / None

9

FAN4/GPIO4

Digital Input

ADM_INTR / Control INTR signal for frequency select

10

FAN5/GPIO5

Digital Input

ADM_NMI / Control NMI signal for frequency select

11

FAN6/GPIO6

Digital Input

ADM_A20MN / Control A20MN signal for frequency select

12

FAN7/GPIO7

Digital Input

ADM_IGNNEN / Control IGNNEN signal for frequency select

13

SCL

Digital Input

SM3_CLK / Open-drain Serial Bus Clock. Requires 1k pull-up
resistor.

14

SDA

Digital I/O

SM3_DATA / Serial Bus Data. Open-drain output. Requires 1k
pull-up resistor.

16

CI (Chassis Intrusion)

Digital Input

FRONTOPEN+03 / An active high input which captures a
Chassis Intrusion event in Bit 7 of Status Register 4. This bit will
remain set until cleared, so long as battery voltage is applied to
the VBAT input, even when the ADM1026 is powered off.

18

PWM

Digital Output

ADM_FAN_PWM / Pulse-width modulated output for control of
fan speed. Open drain.

19

RESET_STBY

Digital Output

RST_BMCRST_L / Power-on Reset. 5 mA driver (open drain),

Advertising