Error Reporting and Handling

Intel® SHG2 DP Server Board Technical Product Specification

Intel Order Number C11343-001

Revision 1.0


46

Code

Error Message

Failure Description

0B51:

Processor #2 with error taken offline

Failed Processor 2 because an error was detected.

0B52

Processor #3 with error taken off line

0B53

Processor #4 with error taken off line

0B5F:

Forced to use CPU with error

Failed Processor 3 because an error was detected.

Failed Processor 4 because an error was detected.

An error detected in the entire CPU.

0B60:

DIMM bank 1 has been disabled

Memory error, memory bank 1 failed

0B61:

DIMM bank 2 has been disabled

0B62:

DIMM bank 3 has been disabled

Memory error, memory bank 2 failed

Memory error, memory bank 3 failed

0B6F:

DIMM bank with error is enabled

An error detected in all the memory

0B70:

The error occurred during temperature sensor
reading

Error while detecting a temperature failure.

0B71:

System temperature out of the range

Temperature error detected.

0B74:

The error occurred during voltage sensor reading

0B75:

System voltage out of the range

Error while detecting voltage

System voltage error

0B7C: The error occurred during redundant power module

confirmation.

The error occurred while retrieving the power
information.

0B80:

BMC Memory Test Failed

BMC device (chip) failed

0B81:

BMC Firmware Code Area CRC check failed

0B82:

BMC core Hardware failure

0B83:

BMC IBF or OBF check failed


Access to BMC address failed

0B90:

BMC Platform Information Area corrupted.

BMC device(chip) failed

0B91:

BMC update firmware corrupted.

0B92:

Internal Use Area of BMC FRU corrupted.

SROM storing chassis information failed

(Available for use except for FRU command and
EMP function)

0B93:

BMC SDR Repository empty.

BMC device (chip) failed

0B94:

IPMB signal lines do not respond.

SMC(Satellite Management Controller) failed

(Available for use except for the access function to
SMC via IPMB)

0B95

BMC FRU device failure.

SROM storing chassis information failed

(Available for use except for FRU command and
EMP function.)

0B96

BMC SDR Repository failure.

BMC device (chip) failed

6.5.4

Liquid Crystal Display (LCD)

There are three users of the LCD: BMC, BIOS, and software. Sometimes they may be using the
LCD simultaneously.

6.5.4.1 BIOS

Usage

The BIOS uses the first line of the LCD. It uses the LCD for messages related to failures and
other conditions. The BIOS generates an LCD message during POST and as a result of errors
handled by the BIOS SMI handler. Unless the LCD has been forcibly reserved by software (via