Logging, General syslog information, Public space parameters – Proxim ORiNOCO AP-2500 User Manual

Page 125

Advertising
background image

125

Public Space Parameters

Example of a Positive Acknowledgment:
<AP COMMAND=”RMTLOG_ACK”>
<ACK_VALUE>OK</ACK_VALUE>
<IP_ADDR>205.23.43.12</IP_ADDR>
<ERROR_CODE>1</ERROR CODE>
</AP>

Example of a Negative Acknowledgment:
<AP COMMAND=”RMTLOG_ACK”>
<ACK_VALUE>ERROR</ACK_VALUE>
<IP_ADDR>205.23.43.12</IP_ADDR>
<ERROR_CODE>5</ERROR CODE>
</AP>

Format for each field:
RESULT_VALUE: OK or ERROR
IP: standard IP format
ERROR_CODE: 1 for OK, or any other number for an error.

Logging

You can configure the AP-2500 to send system events and/or AAA events to network servers using the Syslog
protocol. You can specify a single server to receive both types of messages or you can specify a different server for
each message type.

General Syslog Information

The Syslog message format is defined in RFC 3164 (see

http://www.rfc-editor.org/

).

The AP transmits Syslog messages to the specified server(s) using the well-known UDP Syslog port (514).

You need a Syslog server program running on a network computer to receive Syslog messages from the AP.

Kiwi Enterprises has a freeware Syslog Daemon for Windows operating systems. You can download the
program at

http://www.kiwisyslog.com/

.

Syslog Events are logged according to the level of detail specified by the administrator. Logging only urgent system
messages will create a far smaller, more easily read log then a log of every event the system encounters.
Determine which events to log by selecting a priority defined by the following scale:

Event

Priority

Description

LOG_EMERG

0

system is unusable

LOG_ALERT

1

action must be taken immediately

LOG_CRIT 2

critical

conditions

LOG_ERR

3

error conditions

LOG_WARNING

4

warning conditions

LOG_NOTICE

5

normal but significant condition

LOG_INFO

6

informational

LOG_DEBUG

7

debug-level messages

Advertising