PB Heat Gas Boiler User Manual

Page 42

Advertising
background image

40

Boiler

Model

Input Btu/hr

DOE Heating

Capacity³

Btu/hr

Net I=B=R

Rating¹’²

Btu/hr

Seasonal

Efficiency³

AFUE %

Shipping

Weight

Lbs.

PI-T50

18,000 to 50,000

16,000 to 46,000

40,000

92

58

PI-T80

19,000 to 80,000

17,000 to 74,000

64,000

92

58

PI-80

27,000 to 80,000

25,000 to 74,000

64,000

92

75

PI-140

46,000 to 140,000

43,000 to 129,000

112,000

92

101

PI-199

66,000 to 199,000

61,000 to 183,000

159,000

92

111

Boiler

Model

Fan Speed – RPM

High Fire

Ignition

Low Fire

PI-T50

3200

3000

1250

PI-T80

4700

3000

1200

PI-80

4600

4600

2000

PI-140

4300

2000

1400

PI-199

6000

3745

2100

Table 10.1: Boiler Ratings

Table 10.2: Combustion Air Fan Speed

1.

Net I=B=R ratings are based on an allowance of 1.15.

2.

Consult factory before selecting a boiler for installations having unusual piping and pickup requirements, such as
intermittent system operation, extensive piping systems, etc.

3.

Heating Capacity and Annual Fuel Utilization Efficiency (AFUE) ratings are based on U.S. Government Testing.

Note: These values are subject to change without notice.

BOILER DIMENSIONS & RATINGS

Boiler

Model

Supply &

Return Conn.

(NPT)

Relief Valve

Outlet

(NPT)

Gas Supply

Conn.

(NPT)

Air Inlet &

Vent Conn.

(Sch 40 PVC)

Condensate

Drain Pipe

(NPT)

PI-T50

1-1/4"

3/4"

3/4"

2"

3/4"

PI-T80

1-1/4"

3/4"

3/4"

2"

3/4"

PI-80

1-1/4"

3/4"

3/4"

3"

3/4"

PI-140

1-1/4"

3/4"

3/4"

3"

3/4"

PI-199

1-1/4"

3/4"

3/4"

3"

3/4"

Table 10.3: Connection Sizes

Advertising