Pioneer DVD-V7200 Industrial DVD Player RS-232C User Manual

Page 66

Advertising
background image

PIONEER DVD-V7200 Industrial DVD Player RS-232 Command Protocol Manual

- 58 -

Argument

Function

0 (default)

Normal

64

Audio SQ invalid

128

Video SQ invalid

192

VD/AD SQ invalid

6.16

Register D Set

Function :

The current setting of Register D is rewritten

Format

:

Integer RD

Explanation

:

Register D contains the termination setting of the serial communication

(RS232). There are two choice: “CR”, “CR + LF”. The default of the Register D is 0.

Argument

Function

0 (default)

CR

64

CR + LF

6.17

Print Character

Function :

Characters are written into the User's Display Area

(Not to be issued simultaneously with other commands)

Format

:

Integer PR <CR>

Character string <CR>

Explanation

:

The command writes a character string for one line into the User

Display Area (turn on the User Display Specification in Register A).

Follow the instructions listed below to create printed characters.

1. Specify the line number using an integer in the range 0 ~ 9

2. Enter the command character PR

3. Enter the terminate code <CR>
4. Specify the character string to enter in the next command string

(enter a character string up to 32 characters in length)