Table (b): Outdoor Air Temperature Shifting

Mode:

Outdoor Temperature, X (°C):

Temperature Shift (°C)

Manual Operation

Auto Operation

Cooling/Soft Dry

38

X

1.50

2.00

30

X

38

1.25

1.25

23

X

30

1.25

1.25

X

23

1.75

1.75

Heating

21

X

-2.25

-1.50

17

X

21

-1.75

-1.00

13

X

17

-0.75

0.00

9

X

13

0.25

0.25

5

X

9

1.25

1.00

1

X

5

0.75

1.00

-3

X

1

1.50

1.00

X

-3

1.50

1.00

Table (c): Powerful Mode Shifting

Mode:

Period, X (min):

Temperature Shift (°C)

Cooling

X

20

-2.0

X

20

0.0

Soft Dry

X

20

-1.0

X

20

0.0

Heating

X

20

+3.5

X

20

+3.25

Table (d): Quiet (Lo) Mode Shifting

Mode:

Period, X (min):

Temperature Shift (°C)

Cooling, Soft Dry

20 min

X

50 min

-3.0

50 min

X

110 min

-4.0

110 min

X

440 min

-5.0

Table (e): Fan Speed Shifting

Mode:

Fan Speed:

Temperature Shift (°C)

Cooling

Lo

-0.25

Me-, Me, Me+, Auto

0.00

Hi

+0.25

Soft Dry

All

+0.25

Heating

Lo

+1.50

Me-, Me, Me+, Auto

+0.75

Hi

+0.75

Table (f): Start-Up Shifting

Mode within 60 Minutes from Start-up:

Temperature Shift (°C)

Cooling/Soft Dry

-1.0

Heating

+2.0

16