D. Deodorizing Control

i. Control condition

Control at cooling/dry operation and auto fan speed.

No Deodorizing Control is performed during ON timer standby operation and during Anti-freezing control prevention.

ii. Operation

The odor status is arranged as below and it is shifted as follow.

* When COMP is ON

1

→ 2 → 3

(Shift to 4 when COMP is OFF)

* When COMP is OFF

4

→ 5 → 4 ←→ 5

(Shift to 1 when COMP is ON)

* Start from 4 if the Thermostat is OFF during the start operation.

Odor Status

1

2

3

4

5

4

5

4.5.4...

1

Status Shift

according to COMP

ON

OFF

ON

Status Shift

according

Cooling

zone

40

50

20

90

20

90

.......

to time (s)

Dry zone

ON

Fan Speed

Cooling

zone

OFF

SLo

Auto Fan Speed

SLo

OFF

SLo

OFF

.......

Dry zone

OFF

SLo

OFF

8.1.8. Outdoor Fan Motor Operation

Outdoor fan motor is operated with 15 fan speed. It starts when compressor starts operation and it stops 30 seconds after
compressor stops operation.