1. Relationship between the condition of the air conditioner and pressure and electric current

Cooling Mode

Heating Mode

Condition of the air

conditoner

Low Pressure

High Pressure

Electric current

during operation

Low Pressure

High Pressure

Electric current

during operation

Insufficient refrigerant
(gas leakage)

Clogged capillary tube
or Strainer

Short circuit in the
indoor unit

Heat radiation
deficiency of the
outdoor unit

Inefficient compression

• Carry on the measurements of pressure, electric current, and temperature fifteen minutes after an operation is started.

12.2. Breakdown Self Diagnosis Function

Once abnormality detected during operation, the unit will immediately stop its operation (Timer LED is blinking) and maximum of
three error codes (abnormality) will be saved in memory. The abnormality of the operation can be identified through the below
breakdown diagnosis method:
• Press “CHECK” button at remote control continuously for more than five seconds to turn on the diagnosis mode, “H11” will be

displayed at remote control.

• By pressing the TMER “ ” button once, next error code will be displayed; press “V” button once, previous error code will be

displayed.

• If error code displayed matches the error code saved in unit memory (abnormality detected), four “beep” sounds will be heard

and Power LED will light on. Otherwise, one “beep” sound is heard.

If “CHECK” button is press again during Cooling operation using test run operation mode for 30 seconds, the diagnosis mode will
turn off.