8 - 6

The command responses are received back and include the mute status for all

virtual channels in the “Mics” virtual channel group.

When there are multiple simultaneous control sessions to a SoundStructure

system, the control session that sends commands will also receive command

acknowledgements for all of its commands. Other control sessions will only

receive command acknowledgements from a command entered from another

control session if a parameter value changes.
For example, if a control session queries the value of the mute status, only that

control session will receive the acknowledgement of the mute value. However

if the control session changes the mute state, for example, all control sessions

will receive an acknowledgement.

SoundStructure Device Discovery

SoundStructure Studio uses a discovery mechanism for identifying Sound-

Structure devices on the network. SoundStructure Studio sends a UDP

discovery broadcast using port 52774 and all SoundStructure systems that

receive the broadcast will respond and identify themselves.
If the IP address changes on the SoundStructure device, such as if the dynamic

IP address lease expires and a new IP address is received, it may take up to 75

seconds for the discovery mechanism to restart.
This discovery mechanism only creates network traffic when SoundStructure

Studio is discovering devices caused by the user opening the Connect to

Devices window.
Because both the discovery and command channels use port 52774, traversing

firewalls only requires opening port 52774 for both UDP (for discovery) and

TCP (for commands) to allow for remote access of the SoundStructure device.

Control sessions receive acknowledgements for commands entered in that session
and only receive command acknowledgments from other command sessions if the
other command sessions change the value of a parameter.