Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12

A - 104

Examples

am_hold_time Automixer Hold Time

Description

This parameter defines how long (in ms) the microphone in the specified

automixer group will be considered active after the last detected significant

level on the microphone.

am_last_mic_mode Automixer Last Mic Mode

Description

When this parameter is set to 1, the last mic mode is enabled on the

microphone.

Command

Response

Description

set am_group "Table Mic
1" 1

val am_group "Table Mic
1" 1

Assigns "Table Mic 1" to automixer group 1.

Argument

Argument value

Channel Type

Global Systems

Value Type

Integer

Read/Write Mode

Read/Write

Indices

1-63 : group number

Systems Limits

Minimum: 10, Maximum: 10000

Default

500

User Limits
Supported

No

Argument

Argument value

Channel Type

Virtual Channel

Value Type

Boolean

Read/Write Mode

Read/Write

Phys Chans

Conferencing Mic/Line Input, Sound Reinforcement Mic/Line
Input

Virt Chans

Mono, Stereo

Default

0