Ethernet – Polycom C16 User Manual

Page 345

Advertising
background image

Command Protocol Reference Guide

A - 3

Ethernet

Each SoundStructure device has a rear-panel Ethernet interface for connecting

to the local area network as shown in the following figure. Connect to the

SoundStructure device using port 52774 and telnet communication. There is

no user login required to interface to SoundStructure devices over this port.

Control systems and PCs running SoundStructure Studio may communicate

with SoundStructure over this interface using port 52774. Each

SoundStructure will support multiple simultaneous IP connections from its

Ethernet controller.
Each collection of SoundStructure devices that are linked via the OBAM

interface only requires a single LAN connection to control all the

SoundStructure devices. SoundStructure devices also support having multiple

linked devices with each device connected via Ethernet. Connecting to two

networks could be used to provide redundancy on the same network or can be

PIN 2: TXD
PIN 3: RXD
PIN 5: GROUND
PIN 7: CTS
PIN 8: RTS

LAN

C-LINK2

OBAM

IR

RS-232

REMOTE CONTROL 2

IN

OUT

1

2

1

2

12V

REMOTE CONTROL 1

LAN

Advertising
This manual is related to the following products:

C8, SR12, C12