Command Protocol Reference Guide

A - 113

ir_key_held Key Held On IR Remote

Description

When queried, this parameter returns the keycode value of the last key that

was held on the IR remote. As an event, a status message is generated at an

interval of approximately 100 ms whenever an key is held on the IR remote.

ser_baud RS-232 Baud Rate

Description

This parameter sets the baud rate for the RS-232 port. Hardware flow control

should be enabled for baud rates over 9600 bps (see the ser_flow parameter).

Examples

Argument

Argument value

Channel Type

Virtual Channel

Value Type

Integer

Read/Write Mode

Read/Write

Phys Chans

Infrared Remote Input

Virt Chans

Control

System Limits

Minimum: 0, Maximum: 255

Argument

Argument value

Channel Type

Device-Specific System

Value Type

List

Read/Write Mode

Read/Write

Values

9600 : 9600 bits per second (default)
19200 : 19200 bits per second
38400 : 38400 bits per second
57600 : 57600 bits per second
115200 : 115200 bits per second

Command

Response

Description

set ser_baud 1 9600

val ser_baud 1 9600

Sets the serial port baud rate on device 1 (the first
device) to 9600.