Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12

A - 116

Description

This parameter returns the status of the system. A value of ok indicates that the

system is operating normally. The front-panel LEDs on all the devices will be

green in this condition. A value of warning indicates that a warning condition

has occurred. A warning condition is usually due to a configuration error that

can be corrected via software. The front-panel LEDs on all of the devices will

be yellow in this condition. A value of error indicated that an error has

occurred that is most likely due to a hardware failure or some other serious

condition that can’t be corrected via software. The front-panel LEDs on one or

more of the linked devices will be red in this condition.

dev_temp Internal Temperature

Description

This parameter returns the temperature (in degrees C) from of one of the

internal temperature sensors. The temperature sensors have the following

locations by index. 1 is at the back right, underneath the plug-in slot. 2 is near

the center of the analog input circuitry. 3 is at the front right, in front of the

power supply.

Value Type

List

Read/Write Mode

Read-Only

Values

ok : Normal operation
warning : Warning condition
error : Error condition

Argument

Argument value

Argument

Argument value

Channel Type

Device-Specific System

Value Type

Floating-Point

Read/Write Mode

Read-Only

Indices

1-3 : Temperature sensor index

System Limits

Minimum: -40.0, Maximum: 125.0, Resolution: 0.1