Warning – Parker Products OEM650X User Manual

Page 12

Advertising
background image

5

OEM650/OEM650X • INSTALLATION

WARNING

The drive and motor should be mounted to a heatsink. Drive mounting does not affect

the following tests, but if you operate the OEM650/OEM650X for extended periods

without proper mounting, it will damage the drive and/or motor. When you complete

the quick tests, remove power to the drive.

Perform installation and test procedures in a properly grounded
environment. Compumotor recommends the use of a grounding
strap.

1. Remove the cover by applying pressure to the 25-pin D connector.

To remove cover,
push the 25-pin D
connector in while
holding the sides of
the unit.

11

10

9

8

7

6

5

4

3

2

1

Jumpers

A

When the cover is
removed, the
jumpers will be
visible at the upper
portion of the unit.

B

Auto

Test

Auto

Standby

Motor

Waveform

Shape

Motor

Resolution

Motor

Current

Range

Enlarged view of jumpers

Compumotor

5500 Business Park Dr.
Rohnert Park, CA 94928

Prod: Ш571Ш2-2-6-Ш17-Ш1Ш

Made In USA

Compumotor

5500 Business Park Dr.
Rohnert Park, CA 94928

Made In USA

Prod: Ш571Ш2-2-6-Ш17-Ш1Ш

Figure 2-1. OEM650/OEM650X Jumpers

2. To test the system, you will use the Automatic Test function,

jumper

11

. Remove jumper

11

to enable the function (save for

later installation). Do not remove any other jumpers. When
power is applied to the drive with jumper 11 removed, the Auto-
matic Test function will rotate the motor in an Alternating mode
approximately 6 revolutions at 1 rps.