TROUBLESHOOTING • OEM650/OEM650X

42

Determine if the problem is mechanical, electrical, or software-
related. Can you repeat or re-create the problem? Random events
may appear to be related, but they may not be contributing factors to
your problem. Investigate the events that occur before the subse-
quent system problem.

You may be experiencing more than one problem. You must solve
one problem at a time. Document all testing and problem isolation
procedures. You may need to review and consult these notes later.
This will also prevent you from duplicating your testing efforts.

Once you isolate the problem, take the necessary steps to resolve it.
Use the solutions in this chapter. If your system’s problem persists,
call Compumotor at 800-358-9070.

Front Panel LEDs

There are two LEDs on the front panel of the OEM650/OEM650X
(refer to Figure 5-1).

OEM

s

e

r

i

e

s

REMOTE

REF

CURRENT

DUMP

VDC+

VDC-

A+

A-

B+

B-

POWER

FAULT

Green POWER LED
Red FAULT LED

Figure 5-1. OEM650/OEM650X LEDs

The FAULT LED is red and turns on when the amplifier is disabled.
This LED is activated when any of the following conditions occur:

❏ Motor short circuit detected
❏ Drive over-temperature
❏ Motor winding open
❏ Internal fault detected

The POWER LED is green and turns on when the internal bias
supply is operating and providing +5V.

Common Problems and Solutions

The following table will help you eradicate most of the problems you
might have with the OEM650/OEM650X.