20

Resolution

JU2

JU3

JU4

JU5

50,800 Steps/Rev

on

on

on

off

50,000 Steps/Rev

on

on

off

on

36,000 Steps/Rev

on

on

off

off

25,600 Steps/Rev

on

off

on

on

25,400 Steps/Rev

on

off

on

off

25,000 Steps/Rev *

on

on

on

on

21,600 Steps/Rev

on

off

off

on

20,000 Steps/Rev

on

off

off

off

18,000 Steps/Rev

off

on

on

on

12,800 Steps/Rev

off

on

on

off

10,000 Steps/Rev

off

on

off

on

5,000 Steps/Rev

off

on

off

off

2,000 Steps/Rev

off

off

on

on

1,000 Steps/Rev

off

off

on

off

400 Steps/Rev

off

off

off

on

200 Steps/Rev

off

off

off

off

* Default Setting

Table 2-10. Motor Resolution Jumper Settings

Your indexer (if you are using an OEM650) and drive should be set to
the same resolution. If the drive and indexer’s motor resolution
settings do not match, commanded accelerations and velocities will
not be performed accurately.

Jumpers #6 - #8: Motor Waveform Shape

These jumpers control the shape or waveform of the commanded
motor current. Motor waveforms can reduce resonance problems
and allow the motor to run smoothly. This function will not operate
when the 200-step or 400-step motor resolutions are used.

Motor Waveform

JU6

JU7

JU8

Pure sine

off

off

on

-2% 3rd Harmonic

off

on

off

-4% 3rd Harmonic*

on

on

on

-4% 3rd Harmonic

off

off

off

-4% 3rd Harmonic

off

on

on

-6% 3rd Harmonic

on

off

off

-8% 3rd Harmonic

on

off

on

-10% 3rd Harmonic

on

on

off

* Default Setting

Table 2-11. Motor Waveform Jumper Settings

Jumpers #9 - #10: Auto Standby

The Automatic Standby function allows the motor to cool when it is
not moving. This function reduces the current to the motor when
the drive does not receive a step pulse for one second. Full current
is restored upon the first step pulse that the drive receives. Do not
use this function in systems that use an indexer and an encoder for
position maintenance
. If used in this environment, the system will go
in and out of the Auto Standby mode
.