15

OEM650/OEM650X • INSTALLATION

2

3

4

5

6

7

8

5

10

15

20

25

30

35

40

OEM57-51

P

OEM57-40

S

OEM57-40

P

OEM57-51

S

OEM57-83

S

OEM83-62

*

OEM83-93

*

OEM83-135

*

OEM57-83

P

Power Dissipated

(Watts)

Drive Current

(Amps)

S—Series Configuration
P—Parallel Configuration
*—34 size motors are internally wired in Parallel

Figure 2-11. OEM650/OEM650X Power Dissipation

Over-Temperature Protection

The OEM650/OEM650X is over-temperature protected. The drive will
shut down if its heatplate temperature exceeds 58°C (136°F). To
measure drive temperature under operating conditions, position a
thermal probe on the left edge of the heatplate, approximately 1.5"
from the top of the drive, as shown in Figure 2-12.

Compumotor

OEM

OEM

s

e

r

Measure heatplate temperature
on left side, 1.5" from top of drive.

Figure 2-12. Heatplate Temperature Measurement

To keep the drive cool, and ensure that over-temperature protection
does not unexpectedly shut down the drive, the temperature of the
mounting surface adjacent to the drive should not exceed 55°C
(131°F).