Parker Products OEM650X User Manual

Page 19

Advertising
background image

INSTALLATION • OEM650/OEM650X

12

Handshaking is not supported. Terminals should be set for full
duplex mode.

3. Apply power. The OEM’s green power LED should be on. If the

red

FAULT

LED is on, consult Chapter 4, Maintenance & Trouble-

shooting.

This test assumes that your indexer’s motor resolution is set to
25,000 steps/rev. This is the default motor resolution setting
for the OEM650X
.

4. Enter and run the following command sequence to test the

system.

Command

Description

MN

Sets unit to Normal mode

LD3

Disables CW & CCW Limits

A1Ø

Set acceleration to 10 rps

2

V1Ø

Set velocity to 10 rps

D25ØØØ

Set move distance to 1 CW revolution

G

Initiate move (Go)

H

Reverse move direction (CCW)

G

Initiate move (Go)

5. After verifying that the motor moves CW and CCW, turn off power.

CAUTION

RS-232C signals are not on pins 2, 3, and 7 on the 25-pin D connector.

OEM

s

e

r

i

e

s

REMOTE

REF

CURRENT

DUMP

VDC+

VDC-

A+

A-

B+

B-

POWER

FAULT

Power

Supply +

-

Refer to Figures 2-2 and
2-3 for specific motor
wiring instructions

OEM

Series

Motor

14 Tx

7 GND

15 Rx

Rx

Tx

GND

Figure 2-8. OEM650X Test Configuration

Advertising
This manual is related to the following products: