Lamp Hour Reset: When you replace the projector lamp (refer to Lamp

Replacement on page 63), you should also reset the lamp hour counter. To do

this, select Lamp Hour Reset from the Service menu, then press ENTER. Press

ENTER again to confirm the reset. Or, to cancel the operation, press on the

remote to highlight No, then press ENTER.

Factory Reset: Select Factory Reset from the Service menu to restore all

projector settings – except those listed below – to their factory-default values:
• Lamp Hours
• User Memory 1 / User Memory 2
• ISF Day
• ISF Night
• Model Name / Serial Number
• Language

Blue Only: This feature removes all red and green color information from the

image, and is useful for color-calibrating the projector or other video

components.

Test Patterns: The PD8130/PD8150 has numerous internal test patterns that are

useful to technicians for advanced calibration, measurement and fault isolation

purposes. To access them, select Test Patterns from the Service menu and set it

to On.

The available test patterns are:
• White
• Black
• Red
• Green
• Blue
• Cyan
• Magenta
• Yellow
• ANSI Checkerboard
• Horizontal Gray Ramp
• Focus Grid

Press or on the remote control unit or built-in keypad to cycle through the

test patterns.

Reset the Lamp Hour counter ONLY after you replace the

lamp. Otherwise, the reported “Lamp Hours” will be

inaccurate.

Do not exceed the recommended lamp life. An old lamp

becomes increasingly fragile and prone to sudden failure.