ACK ACTION

Set ACK ACTION to program the frequency at which an alert message is displayed after the alert
condition has been acknowledged. The following settings are available:

ALWAYS ON: The alert message is displayed until alert conditions are cleared.

OFF 8 HRS: The alert message is turned off for 8 hours. Message returns after 8 hours if the
alert condition persists.

OFF 24 HRS: The alert message is turned off for 24 hours. Message returns after 24 hours if
the alert condition persists.

OFF 48 HRS: The alert message is turned off for 48 hours. Message returns after 48 hours if the
alert condition persists.

ACTIVATE AUX

This setting activates an auxiliary when an alert condition exists. Settings include the following
options:

NONE (default): Not activated.

1: An alert condition will close AUX 1.

2: An alert condition will close AUX 2.

CURRENT READING

The Current Reading menu displays the existing status of temperature, pressure, and dew point
inside the dome system. An arrow displayed to the left of a menu item denotes that an alert
condition exists.

An up arrow indicates the reading is over the threshold. A down arrow indicates the reading is
below the threshold.

The high temperature alert occurs if the temperature is above 140°F (60°C).

The low temperature alert occurs if the temperature is below -40°F (-40°C).

The high pressure alert occurs if the pressure is above 13 PSIG.

The low pressure alert occurs if the pressure is below 1 PSIG.

The dew point (high humidity) alert occurs if the difference between the temperature and the dew
point is less than or equal to 3°C.

Note: The normal operating temperature inside the unit will be greater than the temperature
outside the back box due to the heat emitted by the system’s electronics.

RESET ALERT

Reset alert clears the alert condition and removes the alert label from the monitor. The system
automatically checks internal conditions 60 seconds after reset. If conditions are still unacceptable,
the alert label reappears on the screen indicating further corrective action is required.

EXIT

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT

RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM

BACK
EXIT

<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>

DOME SETTINGS

REPEAT
ACK ACTION
ACTIVATE AUX
<CURRENT READING>
RESET ALERT

BACK
EXIT

ALERT

TEMPERATURE

DEWPOINT

PRESSURE

REFRESH

BACK
EXIT

CURRENT READING