Paradyne IP DSLAM GranDSLAM 4200 User Manual

Page 37

Advertising
background image

2. Cabling

4200-A2-GN20-40

January 2004

2-13

Procedure

To connect the ALARM interface:

1. Strip the tips of the alarm source wires (about 1/2 inch or 12.7 mm in length).

2. For Model 4210, insert the wires into the 3-position plug. Securely fasten each

wire by tightening the screw above it.

For Models 4220/4230, use a screwdriver to press the orange spring tab in
while inserting the wire into the hole below it.

NOTE:

For all models, the insulation should be fully within the plug and no bare
wire should be exposed outside of the plug.

3. Insert the plug into the ALARM interface on the front panel of the

GranDSLAM 4200.

4. If the GranDSLAM 4200 is in a rack, dress the cable to the left and secure it to

the rail with a cable tie.

02-17283

02-17328

Spring

Tab

Advertising