Model 4210 alarm/bits connector, Model 4210 alarm/bits, Connector – Paradyne IP DSLAM GranDSLAM 4200 User Manual

Page 56

Advertising
background image

A. Connectors and Pin Assignments

A-4

January 2004

4200-A2-GN20-40

Model 4210 ALARM/BITS Connector

The alarm relay reports major alarms through the ALARM connector (top row of
contacts on the ALARM/BITS terminal block) on the front panel of the GranDSLAM
Model 4210. The BITS connector (bottom row of contacts, pins 1–3) is for future
use.

The alarm contacts are closed during normal operation. They open in response to
loss of power, hardware failure, or other alarm conditions. The maximum rated
load for the alarm relays is:

„

30 VDC: 1.0 Amp

„

60 VDC: 0.6 Amp

„

60 VAC: 0.6 Amp

Table A-4.

Model 4210 ALARM/BITS
Connector Pinouts

Signal

Direction

Pin

BITS Tip

In

1

BITS Ring

In

2

BITS Shield

Ground

3

Major Alarm

Out

4

Common

Out

5

Minor Alarm

Out

6

02-17340

3 2 1

6 5 4

Advertising