Models 4220/4230 alarm/bits connector – Paradyne IP DSLAM GranDSLAM 4200 User Manual

Page 57

Advertising
background image

A. Connectors and Pin Assignments

4200-A2-GN20-40

January 2004

A-5

Models 4220/4230 ALARM/BITS Connector

The alarm relay reports major alarms through the ALARM connector (top row of
contacts on the ALARM/BITS terminal block) on the front panel of the GranDSLAM
Models 4220 and 4230. The BITS connector (bottom row of contacts, pins 1–5) is
for future use.

The alarm contacts are closed during normal operation. They open in response to
loss of power, hardware failure, or other alarm conditions. The maximum rated
load for the alarm relays is:

„

30 VDC: 1.0 Amp

„

60 VDC: 0.6 Amp

„

60 VAC: 0.6 Amp

Table A-5.

Models 4220/4230 ALARM/BITS
Connector Pinouts

Signal

Direction

Pin

BITS Tip

In

1

BITS Ring

In

2

BITS Shield

Ground

3

4

5

Major Alarm

Out

6

Common

Out

7

Minor Alarm

Out

8

Alarm Sense +

In

9

Alarm Sense –

In

10

02-17341

5 4 3 2 1

10 9 8 7 6

Advertising