2) When it reaches the switch-off time, the heat pump water heater will

automatically shut down.

3) Press the timer-on

button again, and the set up is cancelled.

4) If the on/off

button is pressed while the unit is under the timer-off

setting, the unit will shut down immediately. The timer setting is
cancelled.

5) Timer-On and Timer-Off cannot be set at the same time.


Coercive Defrosting

1) Press the

button, the heater will go into the defrost mode.

2) After 3 minutes, when the units coil temperature has reached 10°C or the

time of defrost reaches 8 minutes, defrosting is stopped.

3) After exiting the defrost mode, the heater will stop operation for 3

minutes, then it will run in the mode before defrosting. (This key is invalid
for single mode water chiller)