9 - problems and solutions – Premier PHP HWC-260 User Manual

Page 21

Advertising
background image

Premier Heat Pumps – Water Heater and Chiller Manual

Page 21

9 - Problems and Solutions

Please refer to the table below for the most common problems. These can often
be solved by reading the table below. If nothing corresponds to the list, or if the
solutions applied do not solve the problem, contact your retailer

Problem

Observation

Probable Cause

Explanation/Solution

The heat pump does
not start

Blank display

No electrical feed or
power supply

Check the plug and
electrical connection.
Check the line circuit
breaker

The heat pump does
not start

Screen on

Low voltage

Find out reason and
repair

The heat pump starts
and stops within a
few minutes

Refrigerant circuit is
damaged

Check leakage, charge
refrigerant with correct
amount.
Change compressor
repair damaged
refrigerant circuit

The temperature of
the water heater
increases very slowly

The heat pump works

Water temperature and
ambient temperature too
low Water amount used
continuously too large.

Water is running
under
the heat pump

Water condensate come
from the condenser and
is part of normal
operation

Attach the plastic
conduit to the black
plastic outlet and direct
the water away from
the unit

The condensates are
formed in humid
conditions on the cooling
fins of the evaporator.
Install the conduit to
direct the water away
from the machine

The thickness of the
frost is thin

Ambient temperature is
too low

The frost is entailed by
the freezing of the
humid air on the wings
of the evaporator. It's
quite natural and the
heat pump is going to
defrost. Consider the
wintering of the heat
pump.

Some frost appears
outside, on the wings
of the evaporator

The thickness of the
frost is thick (the
blades of the ventilator
may rub on the ice
much more on the
inside)

The de-icing probe or
the thermic circuit
breaker does not work

Stop the heat pump and
call your retailer

The pressure of the
refrigerant shown on
the manometer is very
low

Loss of refrigerant from
the unit

The heat pump
works but the
temperature of the
water does not rise
(*)

The pressure of the
manometer
is right

Breakdown or abnormal
wear of the compressor

Stop the heat pump and
call your retailer or a
refrigeration technician