Serial Interface

13-11

Clock synchronous mode timing

<Transmission>

• One-byte transfer with 8-bit data length and parity on

Fig. 13-2-3 Timing Chart (1)

• Two-byte transfer with 8-bit data length and parity off

Fig. 13-2-4 Timing Chart (2)

When transmission is enabled, transmission starts when data is written to SC0TXB.
Continuous transmission is possible by writing data to SC0TXB again while transmission is in progress.

During a 7-bit transfer, the MSB (bit 7) is ignored.

The SC0TXF flag is set to "1" when data is written to SC0TXB, and is set to "0" at the end of transmission.
The SC0TBF flag is set to "1" when data is written to SC0TXB, and is set to "0" at the start of transmission.

bp1

bp2

bp3

bp4

bp5

bp6

bp7

PTY

bp0

SBO pin

SBT pin

Data write

SC0TXF flag

SC0TBF flag

Interrupt request
(when set to “transmission buffer
empty”)

Interrupt request
(when set to “transmission end”)

bp1 bp2 bp3 bp4 bp5 bp6 bp7

bp0

bp1 bp2 bp3 bp4 bp5 bp6 bp7

bp0

SBO pin

SBT pin

Data write

SC0TXF flag

SC0TBF flag

Interrupt request
(when set to “transmission buffer
empty”)

Interrupt request
(when set to “transmission end”)

Advertising