31

Recording

Set the video input selector switch to the
VIDEO IN position.

1

2. Recording using the VIDEO IN

connector

Press the REC button and PLAY button at the
same time.
Recording now starts.

2

<Notes>

O

If the video signals are not supplied to the VIDEO
IN connector, the mismatching detector circuit is
activated, the unit is set to the REC PAUSE mode,
and recording is not commenced.

O

The detector circuit is activated and the unit is set
to the REC PAUSE mode also when the signals are
interrupted during recording.
When the signals are restored, recording will
automatically recommence.
(The frame-to-frame continuity mode can be
changed using setup menu item No. 110.)

When the detector circuit is activated in the above
way and the REC PAUSE mode is established, error
code [E-A0] and the time data will be displayed
alternately in the status display window.

Press the unit’s STOP button when recording is
to be ended.

3

3. To stop the recording temporarily

Press the unit’s PAUSE/STILL button or
camera’s VTR start/stop button.
The unit is set to the REC PAUSE mode, and the
PAUSE/STILL lamp flashes.

1

<Notes>

O

When recording was commenced using the
camera’s VTR start/stop button, the operation
cannot be temporarily stopped using the unit’s
PAUSE/STILL button.

O

When the REC PAUSE mode continues, the unit
will reverse the tape for several frames every 2
minutes to protect the cylinder heads and tape.
When the REC PAUSE mode has continued for 30
minutes, the tape is unloaded, the standby OFF
(half-loading) mode is established, and the
CASSETTE IN lamp flashes.

To end the recording, press the unit’s
PAUSE/STILL button or camera’s VTR
start/stop button.

2

However, recording will only be continued if ON has been
selected as the setup menu item No. 130 (NO VIDEO REC)
setting.
In this case, input signal error is indicated by the warning
lamp and alarm.

1•2

(1•2)

2

3

1

Advertising