Track merge, Measure copy, Part iv sequencer – Panasonic SX-KN7000 User Manual

Page 102

Advertising
background image

TRACK MERGE

Merge the recorded contents of two tracks
(source tracks) and store the merged contents
in a third track (destination track).
• When the TRACK MERGE function is ex-

ecuted, the data is erased from the two source
tracks.

1.

Select the two source tracks (FROM).

• On the FROM side, use the TRACK

and

buttons to select the two source tracks.

• You cannot select the track to which the CON-

TROL, RHYTHM or CHORD part has been
assigned.

• If the part assigned to the left source track

(“left” meaning its position on the TRACK
MERGE display) is different from the part as-
signed to the right source track, when the parts
are merged in the destination track, the new
track is assigned the same part as the left
track.

2.

Select the destination track (TO).

• Use the TRACK

and

buttons to the right

of the display to specify the track number.

3.

Press the OK button.

• The confirmation display appears. Press the

YES button to execute the function, or press
the NO button to cancel the function.

MEASURE COPY

Copy recorded data of specified measures to a
specified point.
• On the destination track, the new data re-

places the current measure contents.

1.

Specify the measures you wish to copy from
the source track (FROM).

• On the FROM side, specify the settings with

the corresponding buttons.

TRACK:

Specify the track number you wish to copy
the measures from.

• You cannot select the track for the RHYTHM

part or CHORD part in which a repeat com-
mand has been stored.

• If ALL is selected, the specified measures

are copied to all tracks at the same time.

FIRST MEASURE:

Specify the first measure to copy.

LAST MEASURE:

Specify the last measure to copy.

2.

Specify where you wish to copy the selected
measures to.

• On the TO side, specify the settings with the

corresponding buttons.

TRACK:

Specify the track number you wish to copy
to.

• Measures in a track for the CONTROL,

RHYTHM or CHORD part can be copied
only to the same track.

START MEASURE:

Specify the start point to copy the selected
measures to.

REPEAT:

Specify the number of times the selected
measures are to be repeated.

3.

Press the OK button.

• The confirmation display appears. Press the

YES button to execute the function, or press
the NO button to cancel the function.

• Note that if the END command is included in

the source data, it is also copied. Any data
following the END command is not copied.

Se

q

u

e

n

c

e

r

Part IV

Sequencer

102

QQTG0671

Advertising