Moistening Problems (envelopes don't seal)

Symptom

Solution

Incorrect feeding

Make sure you slide the envelope flap under
the blue edge of the feed deck. If you don't, the
moistener can't wet the flap.

Low sealant level

Check the sight glass on the left side of the
moistener tank. If the sealant level is low, add
E-Z Seal® solution until it reaches the bottom of
the fill hole. See the in struc tions in Chapter 10,
Maintenance

.

Dry moistener brush

Try wetting the moistener brush. If the brush drys
out quickly, replace the moistener wick as ex-
plained in Chapter 10, Maintenance.

Dirty moistener brush

Remove the moistener brush. Clean it in plain
water and rinse thoroughly (see Chapter 10,
Maintenance)

Worn moistener brush

Replace the moistener brush (see Chapter 10,
Maintenance)