Pca9665 – NXP Semiconductors PCA9665 User Manual

Page 28

Advertising
background image

PCA9665_2

© NXP B.V. 2006. All rights reserved.

Product data sheet

Rev. 02 — 7 December 2006

28 of 91

NXP Semiconductors

PCA9665

Fm+ parallel bus to I

2

C-bus controller

E0h

Previously
addressed with
General Call; Data
has been received;
ACK has been
returned

Read data byte or

X

X

0

0

0

Data byte will be received and
NACK will be returned.

read data byte

X

X

0

1

0

Data byte will be received and ACK
will be returned.

E8h

Previously
addressed with
General Call; Data
has been received;
NACK has been
returned

Read data byte or

0

X

0

0

0

Switched to not addressed slave
mode; no recognition of own slave
address or General Call address.

read data byte or

0

X

0

1

0

Switched to not addressed slave
mode; own slave address will be
recognized; General Call address
will be recognized if GC = 1.

read data byte or

1

0

0

0

0

Switched to not addressed slave
mode; no recognition of own slave
address or General Call address. A
START condition will be transmitted
when the bus becomes free.

read data byte

1

0

0

1

0

Switched to not addressed slave
mode; own slave address will be
recognized; General Call address
will be recognized if GC = 1. A
START condition will be transmitted
when the bus becomes free.

A0h

A STOP condition or
repeated START
condition has been
received while still
addressed as Slave
Receiver

No I2CDAT action
or

0

X

0

0

0

Switched to not addressed slave
mode; no recognition of own slave
address or General Call address.

No I2CDAT action
or

0

X

0

1

0

Switched to not addressed slave
mode; Own slave address will be
recognized; General Call will be
recognized if GC = 1.

No I2CDAT action
or

1

X

0

0

0

Switched to not addressed slave
mode; no recognition of own slave
address or General Call. A START
condition will be transmitted when
the bus becomes free

No I2CDAT action

1

X

0

1

0

Switched to not addressed slave
mode; Own slave address will be
recognized; General Call will be
recognized if GC = 1. A START
condition will be transmitted when
the bus becomes free.

Table 31.

Slave Receiver Byte mode (MODE = 0)

…continued

Status
code
(I2CSTA)

Status of the
I

2

C-bus and the

PCA9665

Application software response

Next action taken by the
PCA9665

To/from I2CDAT

To I2CCON

STA STO SI

AA

MODE

Advertising